GTI Instruments Series

Selection Logic Behind Aerosol Generator

Selection Logic Behind Aerosol Generator

When selecting a generator, we normally choose between two types of aerosol generators — the Laskin-Nozzle generator and the thermal generator. The two types produce aerosols with different particle size distributions. Their applications also differ. GTI's generator lineup covers both routes.


GTI Aerosol Generator Model  3990-01             

Laskin-Nozzle, Lightweight, Requiring external air source

Aerosol Generator 3990-01 adopts Laskin-Nozzle to produce aerosol. It shall operate once connected to the compressed air. 

Flow Range: 50–8100 cfm 

Concentration Range: 10–100 µg/L

Generator Type: 1~6 Laskin-Nozzles

Applications: Testing leakage rate for HEPA filter, Nuclear facilities and fuel, Pharmaceutical industries and electronic industries, Medical operating rooms and clean rooms, Biosafety cabinets and clean benches, Food processing and scientific experiments


GTI Aerosol Generator Model 3990-02        

Thermal Way, High Flow, Centralized Aerosol Injection

Aerosol Generator 3990-02 is a thermal generator with the heating time of less than 2 minutes and the flow range covering 500–70,000 cfm. Its applications differ from Laskin-Nozzle. When multiple filters in a clean zone require testing, or filter has only a single test port, aerosol could be injected centrally through the ventilation unit and cover the entire system in a single pass. For pharmaceutical cleanrooms, large air handling unit, and nuclear facilities, 3990-02 will be helpful. It requires an external inert gas supply, like N₂ or CO₂. In addition, it could offer higher flow and concentration upper limits.


GTI Aerosol Generator Model 3990-03  

Laskin-Nozzle, Built-in Compressor

3990-03 overcomes the constraints of the 3990-01. It features a built-in compressor, eliminating the need for an external air source — simply plug in, pour in the aerosol, and it could be ready to work. Flow range 50–2000 cfm, with concentration likewise covering 10–100 µg/L. Suitable for biosafety cabinets, negative-pressure filter units, and mobile clean units. It allows operators to conduct tests in corners without air supply interfaces. 


The Laskin-Nozzle relies on mechanical shear, which is simple in structure and quick to set up. Thermal generator uses an evaporation-condensation route. The system is more complicated. However, it delivers higher flow and concentration. The basis for selection lies not in the equipment itself. It lies in the scale of the test object, the on-site air supply conditions, and the coverage required for a single aerosol generation. Only when the right generator is selected can the generator and the leak detection workflow be properly matched. Only then can the stability of the upstream aerosol be ensured.